Start here
Home / Whole-Home Backup / How a portable generator connects to your house

How a portable generator connects to your house

Last checked November 15, 2026. Researched from manufacturer spec sheets and retailer listings. How we research.
How this site is funded: some links on this page go to manufacturers and retailers, and if you buy through them we may earn a commission at no extra cost to you. Our affiliate programs are being set up now, so links are plain links today. Rankings come from the math on this page, never from payments. Full details on our disclosure page.
Short answer

There are two safe ways in, and one way that is never safe. Way one: extension cords from the generator straight to each appliance. Simple, no electrician, and right for a fridge and a few lights. Way two: the generator plugs into an inlet box, a weatherproof socket on the outside wall, wired to your electrical panel. At the panel, either an interlock kit (a sliding metal plate that makes it impossible for the house to take grid power and generator power at the same time) or a transfer switch (a separate box that switches a chosen set of circuits to the generator) keeps the two power sources apart. The way that is never safe: plugging a generator into a wall outlet or dryer outlet to push power backwards into the panel, called backfeeding. It can kill a utility worker on a line you cannot see, and it is illegal in most places. Everything below is way two, part by part.

The parts, in the order power flows

Follow one electron. The generator sits outside and makes power. A heavy cord carries it to the inlet box. The inlet box is wired through the wall to the panel. At the panel, the interlock or transfer switch decides which circuits get generator power and guarantees the grid is disconnected first. The circuit breakers you already own hand the power to the rooms. Four parts, one job each:

PartWhat it isWhat it does
Generator cordA thick, short cable with twist-lock ends, sized for the generator's biggest outletCarries power from the generator to the wall
Inlet boxA weatherproof socket mounted on the outside wallThe plug point. You connect outside, in the rain, without running a cord through a door or window
Interlock kit or transfer switchA safety device at the electrical panelKeeps grid power and generator power from ever meeting, which is the whole safety story
Your breakersThe panel you already haveHand generator power to the circuits you choose

Interlock kit: the sliding plate

An interlock kit is a metal plate fitted over your existing panel, with a new breaker for the generator input. The plate slides so that only one of two breakers can be on: the main breaker (grid power) or the generator breaker (inlet power). To run on the generator you turn the main breaker off, slide the plate, turn the generator breaker on, and then switch on just the circuits you want to run, one at a time so the generator is never asked for more than it can give. Because it uses your whole panel, any circuit can be chosen: the furnace, the well pump, the fridge circuit, the kitchen lights.

The catch is discipline: the plate guarantees the two sources stay apart, but it cannot stop you from turning on too many circuits at once and overloading the generator. You are the load manager. Interlocks are usually the least expensive panel route because the parts are simple and the electrician's time is short, but the kit must be made for your exact panel model, and many towns want a permit and an inspection for panel work.

Transfer switch: the separate box

A transfer switch is a second, smaller panel mounted beside yours, wired to a chosen set of circuits, typically six to ten: furnace, fridge, well or sump pump, a few lights and outlets. Each chosen circuit gets a switch with three positions: grid, off, generator. In an outage you flip the ones you want to the generator side. The set is decided at install time, which is both the strength and the limit: nobody can accidentally overload the generator with a circuit that was never wired in, and nobody can add the garage freezer later without an electrician.

Manual transfer switches pair with portable generators and battery stations. Automatic ones exist, but they belong to standby generators that start themselves; a portable setup always has a person in the loop, plugging in the cord and flipping the switches. Our transfer switch vs extension cords guide compares this route against plain cords on effort, reach, and who should skip each.

Battery stations plug in the same way

Nothing above cares what made the power. A battery power station with a 240 volt outlet and enough output (the class of an Anker SOLIX F3800 or an EcoFlow DELTA Pro 3) can feed an inlet box through the same cord and run panel circuits, silently and with no fuel, for as long as its battery lasts. Smaller stations without a 240 volt outlet stay on extension cords, which is fine for a fridge-and-lights list. The sizing question is unchanged: the panel route delivers whatever the station can output, and the runtime calculator works out how long it lasts on your list.

Installed battery systems (wall-mounted, wired in permanently by an installer) are the grown-up version of the same idea and live in a different price world. This page is about the portable gear most houses actually buy.

What the install costs, honestly

We are not going to print a price table here, because we could not verify one against a source we trust, and made-up electrician prices would be worse than none. What can be said plainly: the parts are ordinary hardware (an inlet box, a cord, and an interlock kit are modest; a transfer switch box costs more), and the bigger share of the bill is the electrician's time, which varies by region, by panel, and by how far the inlet sits from the panel. A panel that is full, very old, or due for replacement anyway can turn a small job into a bigger one. Get two quotes, ask each electrician which route they would put on their own house, and expect the permit and inspection to be part of the job, not a corner to cut.

The safety rules, all of them

  • Never backfeed. No cord with two plug ends, no generator into a dryer outlet or wall outlet, ever. It energizes lines that utility crews believe are dead.
  • Panel work belongs to a licensed electrician. The inlet, interlock, and transfer switch all live inside your panel. This is not a weekend project, and your insurer and your town agree.
  • Fuel generators run outdoors only, at least 20 feet from the house, exhaust pointed away from windows and doors. Carbon monoxide kills quietly every winter. Battery stations are the indoor-safe exception.
  • Let the generator cool before refueling, and store fuel outside the living space, in approved containers.
  • Turn circuits on one at a time when you switch to generator power, so motor starts (fridge, pump, furnace fan) do not all hit in the same second.

Questions readers ask

Should I get an interlock kit or a transfer switch?

Both keep grid power and generator power apart, which is the safety job. An interlock kit is a sliding plate on your existing panel: it can feed any circuit, but you are the load manager, choosing circuits one at a time so the generator is never overloaded. A transfer switch is a separate box wired to a chosen set of circuits at install time: nobody can overload it with an unwired circuit, and nobody can add a circuit later without an electrician. Interlocks are usually the least expensive route because the parts are simple.

Can a battery power station feed my house panel?

Yes, the same way a fuel generator does. A battery station with a 240 volt outlet and enough output (the Anker SOLIX F3800 or EcoFlow DELTA Pro 3 class) can feed an inlet box through the same cord and run panel circuits, silently and with no fuel, for as long as its battery lasts. Smaller stations without a 240 volt outlet stay on extension cords, which is fine for a fridge-and-lights list.

Why is backfeeding so dangerous?

Plugging a generator into a wall outlet or dryer outlet pushes power backwards into the panel and out onto the street lines. Utility crews working those lines believe they are dead, because the grid is down; backfeeding can energize them and kill a worker on a line you cannot see. It is illegal in most places, and it is the one connection that is never allowed, at any budget.

Your next step: compare the two safe ways in, cords or a switch, side by side.

Transfer switch vs extension cords
Sources and checking. Connection methods and safety rules follow the generator manufacturers' own connection guidance and standard electrical practice: interlock and transfer switch operation as documented by their makers, and the backfeeding and carbon monoxide warnings carried by the US Consumer Product Safety Commission and generator makers. No install prices are quoted because no citable price source was verified for this page (checked November 15, 2026). Figures were checked on November 15, 2026. Prices in this category move weekly, so confirm the current listing before you buy. If you spot an error, tell us at contact@backuppowerguides.com and we will fix it and move the checked date.